<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>riposo &#8211; Tecnocarta Med Srl</title>
	<atom:link href="https://www.tecnocartamed.it/tag-prodotto/riposo/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.tecnocartamed.it</link>
	<description>Tecnocarta Med Srl Taranto</description>
	<lastBuildDate>Mon, 29 Apr 2019 14:21:31 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.2</generator>
	<item>
		<title>ECG BTL 08 S &#8211; 1, 3, 6 canali</title>
		<link>https://www.tecnocartamed.it/prodotto/ecg-btl-08-s-1-3-6-canali/</link>
		
		<dc:creator><![CDATA[Leo]]></dc:creator>
		<pubDate>Mon, 29 Apr 2019 14:21:31 +0000</pubDate>
				<guid isPermaLink="false">https://www.tecnocartamed.it/?post_type=product&#038;p=713</guid>

					<description><![CDATA[ECG a riposo. 1,3,6 canali]]></description>
										<content:encoded><![CDATA[<p>Gli ECG della linea BTL-08 S sono ideali per la loro portabilità e la lunga durata della batteria.</p>
<p>Il display LCD consente di visualizzare un canale ECG selezionato ed altre informazioni correlate come la velocità della carta, ampiezza, etc. Il comfort dell‘utente è garantito da un solo tocco e dal semplice utilizzo del menu.</p>
<table width="548">
<tbody>
<tr>
<td width="283">&nbsp;</td>
<td width="94">
<p style="text-align: center">BTL-08 SD6</p>
</td>
<td style="text-align: center" width="85">BTL-08 SD3</td>
<td width="85">
<p style="text-align: center">BTL-08 SD1</p>
</td>
</tr>
<tr>
<td colspan="4" width="548">UNITA&#8217; ESTERNA</td>
</tr>
<tr>
<td width="283">Display</td>
<td colspan="3" width="265">
<p style="text-align: center">display grafico</p>
</td>
</tr>
<tr>
<td width="283">Dimensioni del display</td>
<td colspan="3" width="265">
<p style="text-align: center">70 × 36 mm</p>
</td>
</tr>
<tr>
<td width="283">Risoluzione schermo</td>
<td colspan="3" width="265">
<p style="text-align: center">128 × 64 px</p>
</td>
</tr>
<tr>
<td width="283">Tastiera</td>
<td colspan="3" width="265">
<p style="text-align: center">alfanumerica e funzioni</p>
</td>
</tr>
<tr>
<td width="283">Controllo del contatto dell&#8217;elettrodo</td>
<td colspan="3" width="265">
<p style="text-align: center">indicazione di contatto di ogni elettrodo</p>
</td>
</tr>
<tr>
<td width="283">Interfaccia</td>
<td colspan="3" width="265">
<p style="text-align: center">RS232, riduzione USB</p>
</td>
</tr>
<tr>
<td width="283">Dimensioni</td>
<td colspan="3" width="265">
<p style="text-align: center">276 × 168 × 74 mm</p>
</td>
</tr>
<tr>
<td width="283">Peso approx.</td>
<td colspan="3" width="265">
<p style="text-align: center">2 kg</p>
</td>
</tr>
<tr>
<td colspan="4" width="548">STAMPANTE</td>
</tr>
<tr>
<td width="283">Larghezza carta</td>
<td colspan="3" width="265">
<p style="text-align: center">58 mm</p>
</td>
</tr>
<tr>
<td width="283">Tipo di carta</td>
<td colspan="3" width="265">
<p style="text-align: center">rotolo</p>
</td>
</tr>
<tr>
<td width="283">Tipo di stampa</td>
<td colspan="3" width="265">
<p style="text-align: center">termica</p>
</td>
</tr>
<tr>
<td width="283">Velocità carta</td>
<td colspan="3" width="265">
<p style="text-align: center">5, 10, 25, 50 mm/s</p>
</td>
</tr>
<tr>
<td colspan="4" width="548">SEGNALE</td>
</tr>
<tr>
<td width="283">Numero di canali</td>
<td width="94">
<p style="text-align: center">6</p>
</td>
<td width="85">
<p style="text-align: center">3</p>
</td>
<td width="85">
<p style="text-align: center">1</p>
</td>
</tr>
<tr>
<td width="283">Numero di derivazioni</td>
<td colspan="3" width="265">
<p style="text-align: center">12</p>
</td>
</tr>
<tr>
<td width="283">Derivazioni mostrate</td>
<td colspan="3" width="265">1</td>
</tr>
<tr>
<td width="283">Derivazioni stampate</td>
<td width="94">
<p style="text-align: center">1, 3, 6</p>
</td>
<td width="85">
<p style="text-align: center">1, 3</p>
</td>
<td width="85">
<p style="text-align: center">1</p>
</td>
</tr>
<tr>
<td width="283">Trasmissione in modalità automatica</td>
<td colspan="3" width="265">
<p style="text-align: center">tempo reale, sincronizzata</p>
</td>
</tr>
<tr>
<td width="283">Localizzazione Pacemaker</td>
<td colspan="3" width="265">
<p style="text-align: center">si</p>
</td>
</tr>
<tr>
<td width="283">Sensibilità</td>
<td colspan="3" width="265">
<p style="text-align: center">2.5, 5, 10, 20 mm/mV</p>
</td>
</tr>
<tr>
<td width="283">Registrazioni salvate (strisce lunghe 10-sec)</td>
<td colspan="3" width="265">
<p style="text-align: center">6</p>
</td>
</tr>
<tr>
<td width="283">Registrazione lunga ECG 1 derivazione/2 derivazioni</td>
<td colspan="3" width="265">
<p style="text-align: center">9 min/no</p>
</td>
</tr>
<tr>
<td colspan="4" width="548">FILTRI DIGITALI</td>
</tr>
<tr>
<td width="283">Filtri per alimentazione adattabili</td>
<td colspan="3" width="265">
<p style="text-align: center">50–60 Hz</p>
</td>
</tr>
<tr>
<td width="283">Filtri per tremori muscolari</td>
<td colspan="3" width="265">
<p style="text-align: center">35, 25 Hz</p>
</td>
</tr>
<tr>
<td width="283">Filtri della linea di base</td>
<td colspan="3" width="265">
<p style="text-align: center">0.05 Hz (3.2 s), 0.11 Hz (1.5 s), 0.25 Hz (0.6 s), 0.50 Hz (0.3 s),<br />
1.50 Hz (0.1 s)</p>
</td>
</tr>
<tr>
<td width="283">Automatico</td>
<td colspan="3" width="265">
<p style="text-align: center">no</p>
</td>
</tr>
<tr>
<td colspan="4" width="548">PROFILI STABILITI DALL&#8217;UTENTE</td>
</tr>
<tr>
<td width="283">No. di profili per modalità auto. e man.</td>
<td colspan="3" width="265">
<p style="text-align: center">3</p>
</td>
</tr>
<tr>
<td width="283">No. di profili per la registrazione lunga dell&#8217;ECG</td>
<td colspan="3" width="265">
<p style="text-align: center">3</p>
</td>
</tr>
<tr>
<td colspan="4" width="548">INDICE DELLE OPZIONI DISPONIBILI</td>
</tr>
<tr>
<td width="283">Estensione dei canali</td>
<td width="94">
<p style="text-align: center">no</p>
</td>
<td width="85">
<p style="text-align: center">3–6</p>
</td>
<td width="85">
<p style="text-align: center">1–3–6</p>
</td>
</tr>
<tr>
<td width="283">Diagnosi (include: media, analisi, interpretazione del testo)</td>
<td width="94">
<p style="text-align: center">opzionale</p>
</td>
<td width="85">
<p style="text-align: center">opzionale</p>
</td>
<td width="85">
<p style="text-align: center">no</p>
</td>
</tr>
<tr>
<td width="283">Connessione al PC con software BTL CardioPoint-ECG</td>
<td width="94">
<p style="text-align: center">opzionale</p>
</td>
<td width="85">
<p style="text-align: center">opzionale</p>
</td>
<td width="85">
<p style="text-align: center">no</p>
</td>
</tr>
<tr>
<td width="283">Ergometria con software BTL CardioPoint-Ergo</td>
<td width="94">
<p style="text-align: center">opzionale</p>
</td>
<td width="85">
<p style="text-align: center">opzionale</p>
</td>
<td width="85">
<p style="text-align: center">no</p>
</td>
</tr>
<tr>
<td colspan="4" width="548">SPECIFICHE TECNICHE</td>
</tr>
<tr>
<td width="283">Alimentazione</td>
<td colspan="3" width="265">
<p style="text-align: center">115/230 V, 50–60 Hz</p>
</td>
</tr>
<tr>
<td width="283">Risposta della frequenza</td>
<td colspan="3" width="265">
<p style="text-align: center">0.05–150 Hz</p>
</td>
</tr>
<tr>
<td width="283">Risoluzione digitale</td>
<td colspan="3" width="265">
<p style="text-align: center">3.9 ?V</p>
</td>
</tr>
<tr>
<td width="283">Conversione A/D</td>
<td colspan="3" width="265">
<p style="text-align: center">13 bit</p>
</td>
</tr>
<tr>
<td width="283">Frequenza di campionamento ECG</td>
<td colspan="3" width="265">
<p style="text-align: center">2 000 Hz</p>
</td>
</tr>
<tr>
<td width="283">Rilevazione Pacemaker</td>
<td colspan="3" width="265">
<p style="text-align: center">100 ?s / circuito riservato con funzione di localizzazione a 40000 Hz</p>
</td>
</tr>
<tr>
<td width="283">Portata dinamica</td>
<td colspan="3" width="265">
<p style="text-align: center">15.9 mV</p>
</td>
</tr>
<tr>
<td width="283">Voltaggio di polarizzazione</td>
<td colspan="3" width="265">
<p style="text-align: center">± 400 mV</p>
</td>
</tr>
<tr>
<td width="283">Max. voltaggio costante</td>
<td colspan="3" width="265">
<p style="text-align: center">± 5 V</p>
</td>
</tr>
<tr>
<td width="283">Impedenza input</td>
<td colspan="3" width="265">
<p style="text-align: center">&gt; 20 MOhm</p>
</td>
</tr>
<tr>
<td width="283">Scarto modalità comune</td>
<td colspan="3" width="265">
<p style="text-align: center">&gt; 100 dB</p>
</td>
</tr>
<tr>
<td width="283">Capacità dell&#8217;accumulatore</td>
<td colspan="3" width="265">
<p style="text-align: center">automatico: fino a 30 stampe<br />
manuale: fino a 35 minuti di stampa<br />
monitoraggio segnale: fino a 75 minuti</p>
</td>
</tr>
<tr>
<td width="283">Tempo di carica</td>
<td colspan="3" width="265">
<p style="text-align: center">max. 3 ore (se completamente scarico)</p>
</td>
</tr>
</tbody>
</table>
<p>Quotazione su richiesta</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">713</post-id>	</item>